COMMERCIAL BUILDING - FINAL

Exterior Inspections

  • Ensure that the bold, readily visible, street address is posted. Numbers/letters should be 6 inches minimum in height.
  • Verify exits are properly identified with exit signs and have required hand / guardrails.
  • Verify Handicapped accessibility is properly installed (correct slope) and identified; signs have minimum 7 foot clearance from ground.
  • Collect all required structural certifications as enumerated on Plan Reviews approval letter.
  • Ensure that sediment control measures are protecting adjoining properties.
  • Ensure that the finished grade, down spouts, and splash blocks are directed away from the building.
  • Determine that the lot improvements, i.e., paving, walks, storm water facilities, entrance culverts, landscaping, miscellaneous structures, etc., are in substantial compliance with the permit documents.
  • Determine that the building is sealed against moisture penetration, i.e., painting, caulking and flashings.
  • Determine that chimneys and flues are terminated in accordance with applicable codes and manufacturers instructions.
  • Ensure that approved window screens are in place, where applicable.
  • Ensure that no emergency vehicles or private homeowner access to the new building is hindered by construction materials or equipment.

Interior Inspections

  • Ensure that all required inspection approvals have been secured, i.e., Plumbing, Electrical, HVAC, Fire Protection and Grading (when applicable).
  • Verify floor levels in stair towers are properly identified.
  • Ensure that the basement is DRY.
  • Determine that handrails and guardrails are installed, where required, at the proper elevations with the required maximum picket/dowel spacing, and that the handrails have the proper handgrip sections, are continuous and are terminated correctly.
  • Ensure that there are interconnected, approved battery backup smoke alarms in each sleeping room, outside of each area in the vicinity of the bedrooms and on each additional story of the dwelling, including the basement (when applicable).
  • Determine that safety glazing is installed in all hazardous locations including hinged, fixed, sliding and storm doors, in fixed panels adjacent to doors, along walking areas (except when horizontal bar is used), in showers and tub enclosures and any glazing less than 60 inches above a drain inlet of a shower or tub.
  • Ensure that the insulation package has been completed in all spaces including crawl spaces, basements, and attics.
  • Ensure that 6'8" minimum headroom still exists in all stairways.