COMMERCIAL PLUMBING - GROUNDWORK
- Ensure that the building sanitary drains and fixture branches are correctly sized, joined, graded, trapped and supported; that they are of approved materials, properly bedded, and supported prior to backfill.
- Ensure that building storm and condensate drains are correctly sized, joined, adequately graded, properly bedded, and supported prior to backfill.
- Ensure that the means to remove storm water/condensate is provided (sump pump, daylight, or other approved means).
- Ensure that any in-ground building water lines are sized correctly; are of approved material and are joined properly; are adequately protected against contamination; and meet the separation requirements of the Plumbing Code.
- Ensure that backwater valve protection is provided, when required.
- Ensure that sump pumps and sewage ejectors , when required, are accessible for maintenance; are properly vented and discharge to an approved watercourse.