  • Determine if the required base material is four inches thick and consists of clean, graded sand, gravel, crushed stone or crushed slag.
  • Determine if a vapor retarder is provided except for slabs located in a detached garage, utility building, or unheated accessory structure.
  • If a vapor retarder is required, then determine if it is a 6 mil visqueen vapor retarder with joints lapped not less than six inches and placed at the bottom of the slab.
  • Determine if the slab is a minimum of 3˝ inches thick.
  • Verify that interior concretes compressive strength at 28 days is at least 2,500 psi and 3,000 psi air entrained, when exposed to weather conditions. (Check delivery tickets)
  • Check and note how the radon depressurization method will be vented: Gas tight “T” into aggregate or through the sealed sump cover.
  • Verify that required and approved perimeter slab insulation is installed properly.