| Advanced Searching... |
|
|
|
| |
RESIDENTIAL BUILDING - SLAB
- Determine if the required base material is four inches thick and consists of clean, graded sand, gravel, crushed stone or crushed slag.
- Determine if a vapor retarder is provided except for slabs located in a detached garage, utility building, or unheated accessory structure.
- If a vapor retarder is required, then determine if it is a 6 mil visqueen vapor retarder with joints lapped not less than six inches and placed at the bottom of the slab.
- Determine if the slab is a minimum of 3˝ inches thick.
- Verify that interior concretes compressive strength at 28 days is at least 2,500 psi and 3,000 psi air entrained, when exposed to weather conditions. (Check delivery tickets)
- Check and note how the radon depressurization method will be vented: Gas tight “T” into aggregate or through the sealed sump cover.
- Verify that required and approved perimeter slab insulation is installed properly.